IEC Listrik | 75 | 150 | 275 | 320 | 385 | 440 | |
Tegangan AC Nominal (50/60Hz) | Uo/Un | 60V | 120 V | 230 V | 230 V | 230 V | 400 V |
Tegangan Operasi Kontinyu Maksimum (AC) | Uc | 75V | 150 V | 275 V | 320 V | 385 V | 440 V |
Arus Pelepasan Nominal (8/20 μs) | In | 20 kA | 20 kA | 20 kA | 20 kA | 10 kA | 10 kA |
Arus Pelepasan Maksimum (8/20 μs) | Imax | 50 kA | 50 kA | 50 kA | 50 kA | 50 kA | 50 kA |
Impulse Discharge Current (10/350 μs) | Iimp | 12,5 kA | 12,5 kA | 12,5 kA | 12,5 kA | 10 kA | 10 kA |
Énergi spésifik | W/Urang Sunda | 39 kJ/Ω | 39 kJ/Ω | 39 kJ/Ω | 39 kJ/Ω | 25 kJ/Ω | 25 kJ/Ω |
muatan | Q | 6.25 Salaku | 6.25 Salaku | 6.25 Salaku | 6.25 Salaku | 5 Salaku | 5 Salaku |
Tingkat panyalindungan tegangan | Up | 0,7 kV | 1 kV | 1,5 kV | 1,6 kV | 1,8 kV | 2 kv |
Waktu Tanggapan | tA | <25 ns | |||||
Sekering Nyadangkeun (maks) | 315 A / 250 A gG | ||||||
Peunteun Arus Sirkuit (AC) | lSCCR | 25 kA / 50 kA | |||||
TOV Tahan 5s | UT | 114 V | 180V | 335V | 335V | 335V | 580V |
TOV 120 mnt | UT | 114 V | 230V | 440V | 440V | 440V | 765V |
modus | Tahan | Aman Gagal | Aman Gagal | Aman Gagal | Aman Gagal | Aman Gagal | |
UL Listrik | |||||||
Tegangan Operasi Kontinyu Maksimum (AC) | MCOV | 75 V | 150 V | 275 V | 320 V | 385 V | 440 V |
Peunteun Protection tegangan | VPR | 300 V | 600 V | 900 V | 1200 V | 1350 V | 1500 V |
Nominal Discharge Ayeuna (8/20μs) | In | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA |
Peunteun Arus Sirkuit (AC) | SCCR | ||||||
100 kA | 200 kA | 150 kA | 150 kA | 150 kA | 200 kA | ||
Mékanis & Lingkungan | |||||||
Kisaran Suhu Operasi | Ta | -40ºF dugi ka +158ºF [-40ºC dugi ka +70ºC] | |||||
Kalembaban Operasi Diidinan | RH | 5%...95% | |||||
Tekanan atmosfir sareng luhurna | 80k Pa ... 106k Pa / -500 m.....2000 m | ||||||
Torsi screw Terminal | Mmax | 39,9 Ibf ·dina [4,5 Nm] | |||||
Bagian Palang Konduktor (maks) | 2 AWG (Padet, Terdampar) / 4 AWG (Fléksibel) | ||||||
35 mm2 (Padet, Terdampar) / 25 mm2 (Fléksibel) | |||||||
Pamasangan | |||||||
35 mm DIN Rel, EN 60715 | |||||||
Gelar panyalindungan | IP 20 (built-in) | ||||||
Bahan Perumahan | Thermoplastic: Extinguishing Gelar UL 94 V-0 | ||||||
Perlindungan termal | Sumuhun | ||||||
Kaayaan Operasi / Indikasi Sesar | Héjo ok / Cacat beureum | ||||||
Kontak Jauh (RC) RC Ngalihkeun Kamampuh Bagian Palang Konduktor RC (maks) | Pilihan AC: 250V / 0,5 A;DC: 250V / 0,1 A;125 V / 0,2 A;75 V / 0,5 A 16 AWG (Padet) / 1,5 mm2 (Padet) |
LY1-B 12.5: Surge Protection, ngetik 1 + 2 ka EN 61643-11 kalayan tampilan fungsi visual.Pikeun panganteur 0 mun 2 (LPZ) luyu jeung konsép zone panyalindungan kilat mun IEC 61312-1.
• Kapasitas nangkep 12,5 kA (10/350 µs) per tiang
• Konsumsi kakuatan<26 mW/kutub
• Tingkat panyalindungan<1.5 kV, ngamungkinkeun panyalindungan alat
• Line nuturkeun quenching ayeuna 25 kA Ipeak
• lncl.caps colokan pikeun labél sambungan
• Encapsulated, celah narik non-extinguishing
• Bisa dipaké dina housings distributor baku
Fokus kana nyayogikeun solusi mong pu salami 5 taun.